FUNC:CVOP
Enables/disables +CV mode (addition of CV mode to CC mode or CR mode).
+CV mode can only be set with an SCPI command. This command is available to maintain compatibility with the PLZ-5W series (PLZ205W/PLZ405W/PLZ1205W).
If +CV mode is enabled, the UVP action (PROGram:VOLTage:PROTection:ACTion) is set to LIMit. The LIMit value changes according to the changes in the voltage (VOLTage) in CV mode.
If +CV mode is disabled, the UVP action is set to OFF (disabled) regardless of TRIP/LIMit setting.
Command
[SOURce:]FUNCtion[:MODE]:CVOPtion[:STATe] {ON|OFF|1|0}
[SOURce:]FUNCtion[:MODE]:CVOPtion[:STATe]?
Parameter
Value | ON(1) | Enabled |
---|---|---|
OFF(0) | Disabled | |
*RST transmission | OFF(0) |
Response
Returns +CV mode enable/disable in boolean format in response to the FUNC:CVOP? query.