PLZ12005WH/PLZ20005WH Electronic Load

Commnunication Interface Mannual


 

ARB:RESP

Sets the response speed for ARB mode.

Command

[SOURce:]ARBitrary:RESPonse {<numeric>|MINimum|MAXimum}

[SOURce:]ARBitrary:RESPonse? {MINimum|MAXimum}

Parameter

Value 0 (off), 500u, 1m, 2m, 5m, 10m, 20m, 50m, 100m
Unit s
*RST transmission MINimum

Response

Returns the response speed in ARB mode in NR3 format in response to the ARB:RESP? query.

Setup

Overview of Command

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Electronic Load  PLZ12005WH/PLZ20005WHElectronic Load PLZ12005WH/PLZ20005WH
Communication Interface Manual