ARB:MAP
Sets the voltage and current values for the specified parts (point index) of the I-V characteristics map.
To reflect this setting in the output, send ARB:APPL.
Command
[SOURce:]ARBitrary[:LEVel][:IMMediate]:MAP <inded>, <voltage>, <current>
[SOURce:]ARBitrary[:LEVel][:IMMediate]:MAP? <index>
Parameter <index>
Specifies the point index of the I-V characteristics map
Value | 2 to maximum value of ARB:COUN |
---|
Point index 1 is fixed to 0 V, 0 A.
The voltage of the point index of the value specified by ARB:COUN is fixed to 808.00 V.
If you try to change it, an error is returned.
Parameter <voltage>
Specifies the voltage (Unit: V)
Parameter <current>
Specifies the current (Unit: A)
Example
ARB:MAP 1, 5.0V, 1.0A
Response
Returns the voltage and current values for the specified point index in the NR3 format in response to ARB:MAP?.