CURR:PROT
Set the overcurrent protection.
Command
[SOURce:]CURRent:PROTection[:LEVel][:OVER] {<value>|MINimum|MAXimum}
[SOURce:]CURRent:PROTection[:LEVel][:OVER]?
Parameter
Value | PLZ164W | 0.03 to 36.3 (Resolution: 10m, Default: 36.3) |
PLZ164WA | 0.03 to 36.3 (Resolution: 10m, Default: 36.3) | |
PLZ164WL | 0.05 to 55.00 (Resolution: 50m, Default: 55.00) | |
PLZ164WH | 0.01 to 9.07 (Resolution: 10m, Default: 9.07) | |
PLZ334W | 0.06 to 72.6 (Resolution: 20m, Default: 72.6) | |
PLZ334WL | 0.1 to 110.0 (Resolution: 20m, Default: 110.0) | |
PLZ334WH | 0.01 to 18.15 (Resolution: 10m, Default: 18.15) | |
PLZ664WA | 0.13 to 145.2 (Resolution: 10m, Default: 145.2) | |
PLZ1004W | 0.20 to 220 (Resolution: 10m, Default: 220) | |
PLZ1004WH | 0.01 to 55 (Resolution: 10m, Default: 55) | |
Unit | A |
Table shows the setting that is specified when *RST or *RCL is sent.
Response
Returns the overcurrent protection setting in the NR3 form in response to CURR:PROT?