Regurated DC Power Supply PWX series

Communication Interface Manual


 

VOLT:LIM:LOW

Sets the undervoltage limit (UVL) trip point.

Command

[SOURce:]VOLTage:LIMit:LOW {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage:LIMit:LOW? {MINimum|MAXimum}

Parameter

Value 0 to the present voltage setting (VOLT; the default value is 0 V)
Unit V
A SCPI error (-222, "Data out of range") occurs if outside the range.

For the setting that is applied when *RST or *RCL is sent, see this table.

If you enable the voltage setting limit (VOLT:LIM:AUTO ON) when the UVP trip point is lower than the voltage setting, the UVP trip point setting is changed to the voltage setting.

Response

Returns the UVL trip point in NR3 format in response to VOLT:LIM:LOW?.

Overview