VOLT:LIM:AUTO
Set whether to limit the voltage setting so that it does not exceed the OVP setting or become lower than the UVP setting.
If you enable the limit when the OVP setting is lower than the voltage setting, the OVP setting will be set to 105 % of the voltage setting.
If you enable the limit when the UVP setting is higher than the voltage setting, the UVP setting will be equal to the voltage setting.
Command
[SOURce:]VOLTage:LIMit:AUTO {ON|OFF|1|0}
[SOURce:]VOLTage:LIMit:AUTO?
Parameter
Value | ON (1) | The voltage setting limit is enabled (default). |
OFF (0) | The voltage setting limit is disabled. |
For the setting that is applied when *RST or *RCL is sent, see this table.
Response
Returns whether the voltage setting limit is enabled in NR1 format in response to VOLT:LIM:AUTO?.