Regurated DC Power Supply PWX series

Communication Interface Manual


 

RES

Sets the internal resistance.

If the variable internal resistance feature (factory options) is in use, this command is valid.

If you are not using the variable internal resistance feature, set this to 0.

Command

[SOURce:]RESistance {<numeric>|MINimum|MAXimum}

[SOURce:]RESistance? {MINimum|MAXimum}

Parameter

Value 0 to the rated output voltage/ rated output current
(The default value is 0.)
Unit OHM
A SCPI error (-222, "Data out of range") occurs if outside the range.

Response

Returns the internal resistance setting in NR3 format in response to RES?.