OUTP:SST
Sets whether soft starts are used.
Use OUTP:SST:TIME to set the rise time.
You cannot turn soft starts on when the action that is performed when the current limit is exceeded is CC (CURR:PROT:STAT OFF) or when the compensation function is set to the soft sensing function or the regulation adjustment function (SYST:CONF:SENS:MODE SENS2|RADJ).
If the EX05-PCR-LE is in use (optional) and the signal source is set to external signal source (FUNC:SOUR EXT), soft start cannot be turned on.
If the EX06-PCR-LE is in use (optional) and the AC voltage is being controlled with an external signal (VOLT:EXT:SOUR VOLT), soft start cannot be turned on.
Command
OUTPut:SSTart[:STATe] {ON|OFF|1|0}
OUTPut:SSTart[:STATe]?
Parameter
Value | ON(1) | The soft start function is turned on. |
OFF(0) | The soft start function is turned off (default). |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns whether soft starts are used in NR1 format in response to OUTP:SST?.