TRIG:SOUR

Sets the condition (trigger source) for actually changing the setting after the sequence 1 group receives INIT / INIT:NAME TRAN.

Command

TRIGger[:SEQuence[1]]:SOURce {IMMediate|BUS}

TRIGger[:SEQuence[1]]:SOURce?

TRIGger[:TRANsient]:SOURce {IMMediate|BUS}

TRIGger[:TRANsient]:SOURce?

Parameter

Value IMM Starts the setting immediately
  BUS Wait for a software trigger (*TRG, TRIG, or IEEE488.1 get (Group Execute Trigger)) to change the setting(Default))

For the setting that is applied when *RST is sent, see Table.

Response

Returns the trigger source of the sequence 1 group as character data in response to TRIG:SOUR?.