VOLT

Sets the voltage.

Command

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [{MINimum|MAXimum}]

Parameter

Value

0 % to 105 % of the rated output voltage(The default value is 0 % of the rated output voltage.)
An SCPI error (-221, "Settings conflict") occurs if VOLT:EXT:SOUR is not set to NONE.

Unit V

For the setting that is applied when *RST is sent, see Table.

Response

Returns the voltage setting in the NR3 form in response to VOLT?. If the voltage value is set using external input, the specified voltage is returned.