FETCh | READ | MEASure subsystem | INPut subsystem
| SENSe subsystem
SOURce subsystem | STATus subsystem | SYSTem subsystemm | TRIGger subsystem
Other commands | IEEE488.2 common commands
|
||
Queries the measured data. | ||
FETC:IMP FETC:ARR:IMP |
Measured value of Impedance measurement (magnitude) | |
FETC:IMP:RES FETC:ARR:IMP:RES |
Measured value of Impedance measurement (resistance) | |
FETC:IMP:REAC FETC:ARR:IMP:REAC |
Measured value of Impedance measurement (reactance) | |
FETC:IMP:PHAS FETC:ARR:IMP:PHAS |
Measured value of Impedance measurement (phase angle) | |
FETC:VOLT FETC:ARR:VOLT |
Measured value of voltage output | |
FETC:VOLT:CYCL FETC:ARR:VOLT:CYCL |
Voltage measurement (Voltage synchronized to the impedance measurement) | |
FETC:CURR FETC:ARR:CURR |
Measured value of current output | |
FETC:CURR:CYCL FETC:ARR:CURR:CYCL |
Current measurement (Current synchronized to the impedance measurement) | |
Starts the measurement and queries the data. | ||
READ:IMP READ:ARR:IMP |
Measured value of Impedance measurement (magnitude) | |
READ:IMP:RES READ:ARR:IMP:RES |
Measured value of Impedance measurement (resistance) | |
READ:IMP:REAC READ:ARR:IMP:REAC |
Measured value of Impedance measurement (reactance) | |
READ:IMP:PHAS READ:ARR:IMP:PHAS |
Measured value of Impedance measurement (phase angle) | |
READ:VOLT READ:ARR:VOLT |
Measured value of voltage output | |
READ:VOLT:CYCL READ:ARR:VOLT:CYCL |
Voltage measurement (Voltage synchronized to the impedance measurement) | |
READ:CURR READ:ARR:CURR |
Measured value of current output | |
READ:CURR:CYCL READ:ARR:CURR:CYCL |
Current measurement (Current synchronized to the impedance measurement) | |
Resets a portion of the settings to default, starts the measurement, and queries the data. | ||
MEAS:IMP MEAS:ARR:IMP |
Measured value of Impedance measurement (magnitude) | |
MEAS:IMP:RES MEAS:ARR:IMP:RES |
Measured value of Impedance measurement (resistance) | |
MEAS:IMP:REAC MEAS:ARR:IMP:REAC |
Measured value of Impedance measurement (reactance) | |
MEAS:IMP:PHAS MEAS:ARR:IMP:PHAS |
Measured value of Impedance measurement (phase angle) | |
MEAS:VOLT MEAS:ARR:VOLT |
Measured value of voltage output | |
MEAS:VOLT:CYCL MEAS:ARR:VOLT:CYCL |
Voltage measurement (Voltage synchronized to the impedance measurement) | |
MEAS:CURR MEAS:ARR:CURR |
Measured value of current output | |
MEAS:CURR:CYCL MEAS:ARR:CURR:CYCL |
Current measurement (Current synchronized to the impedance measurement) |
|
||
INP | Load on/off | |
INP:PROT:CLE | Alarm clear | |
INP:SST:FALL | Soft start falling edge | |
INP:SST:RISE | Soft start rising edge | |
INP:SST:RTIM | Remaining time | |
INP:SENS:CURR | CURRENT SENSING channel | |
INP:SENS:VOLT | VOLTAGE SENSING channel |
|
||
IMP:CURR:AC | Averaging period of the measured value | |
IMP:CURR:AC:RAT | Measuring AC current (percentage) | |
IMP:CURR:AC:FREQ | Measuring frequency | |
IMP:CURR:PULS:DEPT | Pulse depth (current) | |
IMP:CURR:PULS:DEPT:RAT | Pulse depth | |
IMP:CURR:PULS:TRAN | Pulse transition time | |
IMP:CURR:PULS:WIDT | Pulse width | |
IMP:AVER:MOV:CLE | Moving average area | |
IMP:AVER:MOV:COUN | Moving average count | |
IMP:SAMP:POS | Sampling start position | |
IMP:SAMP:REG | Sampling region | |
METH | Measurement method | |
VOLT:PROT:LOW | Voltage sensing undervoltage protection | |
VOLT:PROT:LOW:DEL | Voltage sensing undervoltage protection delay time |
|
||
SOUR:CURR | AC current limit | |
SOUR:CURR:EXT | External electronic load DC current | |
SOUR:CURR:RANG | Electronic load DC current range | |
SOUR:VOLT | Voltage of PLZ-4W Series | |
SOUR:VOLT:RANG | Voltage range of PLZ-4W Series | |
SOUR:VOLT:PROT:LOW | Undervoltage protection | |
SOUR:POW:PROT | PLZ4W OPP activation voltage of the electronic load DC voltage |
|
||
STAT:OPER | Queries the event *1 | |
STAT:OPER:COND | Queries the condition of the register *1 | |
STAT:OPER:ENAB | Enable register *1 | |
STAT:OPER:PTR | Positive transition *1 | |
STAT:OPER:NTR | Negative transition *1 | |
STAT:OPER:MEAS | Queries the event *2 | |
STAT:OPER:MEAS:COND | Queries the condition of the register *2 | |
STAT:OPER:MEAS:ENAB | Enable register *2 | |
STAT:OPER:MEAS:PTR | Positive transition *2 | |
STAT:OPER:MEAS:NTR | Negative transition *2 | |
STAT:OPER:TRIG | Queries the event *3 | |
STAT:OPER:TRIG:COND | Queries the condition of the register *3 | |
STAT:OPER:TRIG:ENAB | Enable register *3 | |
STAT:OPER:TRIG:PTR | Positive transition *3 | |
STAT:OPER:TRIG:NTR | Negative transition *3 | |
STAT:OPER:PROT | Queries the event *4 | |
STAT:OPER:PROT:COND | Queries the condition of the register *4 | |
STAT:OPER:PROT:ENAB | Enable register *4 | |
STAT:OPER:PROT:PTR | Positive transition *4 | |
STAT:OPER:PROT:NTR | Negative transition *4 | |
STAT:PRES | Constructing status data | |
STAT:QUES | Queries the event *5 | |
STAT:QUES:COND | Queries the condition of the register *5 | |
STAT:QUES:ENAB | Enable register *5 | |
STAT:QUES:PTR | Positive transition *5 | |
STAT:QUES:NTR | Negative transition *5 |
*1 | OPERation status register |
*2 | OPERation:MEASuring status register |
*3 | OPERation:TRIGger status register |
*4 | OPERation:PROTecting status register |
*5 | QUEStionable status register |
|
||
SYST:COMM:SER:PACE | Flow conrol condition | |
SYST:ERR | Reads the error information | |
SYST:LOC | Go To Local | |
SYST:REM | Remote Enable | |
SYST:RWL | Local Lock Out | |
SYST:VERS | SCPI revision |
|
||
ABOR | Aborts the sequence 1 and 2 operations | |
INIT | Start the trigger function | |
INIT:SEQ | Sequence 1: Start the trigger function | |
INIT:SEQ2 | Sequence 2: Start the trigger function | |
INIT:SEQ:WAV | Sequence 1: Starts the trigger function while holding the voltage and current waveform data | |
TRIG:COUN | Sequence 1: Trigger count | |
TRIG:SOUR | Sequence 1: Trigger-wait status | |
TRIG:TIM | Sequence 1: Trigger time setting | |
TRIG:SEQ2:COUN | Sequence 2: Trigger count | |
TRIG:SEQ2:SOUR | Sequence 2: Trigger-wait status | |
TRIG:SEQ2:TIM | Sequence 2: Trigger time setting |
|
||
FORM:BORD | Data transmission/recording mode | |
FORM:PAGE:LENG | Length of the data to be transferred | |
FORM:PAGE:STAR | Start point of the data to be transferred | |
TRAC | Voltage waveform data or current waveform data |
|
||
*CLS | Clears the status data structures. | |
*ESE | Sets the event status enable register bits. | |
*ESR | Queries the event status register. | |
*IDN | Queries the identification string (manufacturer information). | |
*OPC | Causes the device to generate the operation complete message in the event status register when all pending selected device operations have been finished. | |
*RCL | Recalls the contents saved to the memory. | |
*RST | Performs a device reset. Configures the KFM2150 to a known condition independent from the usage history of the device. | |
*SAV | Saves the current settings to the memory. | |
*SRE | Sets the service request enable register bits. | |
*STB | Reads the status byte and master summary status bits. | |
*TRG | Trigger command | |
*TST | Since there is no self-test function built into the KFM2150. | |
*WAI | Prevents the device from executing subsequent commands or queries until the No Operation Pending flag becomes true. |