OPERation:MEASuring / OPERation:TRIGger status register
The MEASuring and TRIGger status registers indicate measuring or trigger-wait status of the KFM2150.
Only bits 1 and 2 are used.
Table 10 MEASuring/TRIGger status register (STATus:OPERation:MEASuring/STATus:OPERation:TRIGger)
Bit | Bit Weight | Bit Name | Description |
0 | 1 | Not Used | Not Used |
1 | 2 | SEQ1 (SEQuence1) | Impedance measurement |
2 | 4 | SEQ2 (SEQuence2) | Voltage and current measurement |
3 | 8 | Not Used | Not Used |
4 | 16 | Not Used | Not Used |
5 | 32 | Not Used | Not used |
6 | 64 | Not Used | Not used |
7 | 128 | Not Used | Not Used |
8 | 256 | Not Used | Not Used |
9 | 512 | Not Used | Not Used |
10 | 1024 | Not Used | Not Used |
11 | 2048 | Not Used | Not Used |
12 | 4096 | Not Used | Not Used |
13 | 8192 | Not Used | Not used |
14 | 16384 | Not Used | Not used |
15 | 32768 | Not Used | Always zero |
STAT:OPER:MEAS / STAT:OPER:TRIG
Queries the event of the MEASuring / TRIGger status register.
A query clears the contents of the register.
Command
STATus:OPERation:MEASuring[:EVENt]?
STATus:OPERation:TRIGger[:EVENt]?
Response
Returns the event of the MEASuring / TRIGger status register in the NR1 form.
STAT:OPER:MEAS:COND / STAT:OPER:TRIG:COND
Queries the condition of the MEASuring / TRIGger status register.
A query does not clear the contents of the register.
Command
STATus:OPERation:MEASuring:CONDtion?
STATus:OPERation:TRIGger:CONDtion?
Response
Returns the condition of the MEASuring / TRIGger status register in the NR1 form.
STAT:OPER:MEAS:ENAB / STAT:OPER:TRIG:ENAB
Sets the enable register of the MEASuring / TRIGger status register.
Command
STATus:OPERation:MEASuring:ENABle <NR1>
STATus:OPERation:MEASuring:ENABle?
STATus:OPERation:TRIGger:ENABle <NR1>
STATus:OPERation:TRIGger:ENABle?
Parameter
Value: 0 to 32767
Response
Returns the enable register setting of the MEASuring / TRIGger status register in the NR1 form.
STAT:OPER:MEAS:PTR / STAT:OPER:TRIG:PTR
Sets the positive transition of the MEASuring / TRIGger status register.
Command
STATus:OPERation:MEASuring:PTRansition <NR1>
STATus:OPERation:MEASuring:PTRansition?
STATus:OPERation:TRIGger:PTRansition <NR1>
STATus:OPERation:TRIGger:PTRansition?
Parameter
Value: 0 to 32767
Response
Returns the positive transition of the MEASuring / TRIGger status register in the NR1 form.
STAT:OPER:MEAS:NTR / STAT:OPER:TRIG:NTR
Sets the negative transition of the MEASuring / TRIGger status register.
Command
STATus:OPERation:MEASuring:NTRansition <NR1>
STATus:OPERation:MEASuring:NTRansition?
STATus:OPERation:TRIGger:NTRansition <NR1>
STATus:OPERation:TRIGger:NTRansition?
Parameter
Value: 0 to 32767
Response
Returns the negative transition of the MEASuring / TRIGger status register in the NR1 form.