Voltage measurement
Sets the activation voltage of the voltage sensing undervoltage protection (SENSE UVP).
Command
[SENSe:]VOLTage[:DC]:PROTection:LOWer {<numeric>|MIN|MAX|DEF}
[SENSe:]VOLTage[:DC]:PROTection:LOWer? [{MIN|MAX]}
Parameter
Value: | -2 to 150 (default: -2) |
Unit: | V |
Table 4 shows the setting that is specified when *RST , *RCL or MEAS? is sent.
Response
Returns the activation voltage of the voltage sensing undervoltage protection in the NR3 form in response to VOLT:PROT:LOW?.
Sets the activation delay time of the voltage sensing undervoltage protection.
Command
[SENSe:]VOLTage[:DC]:PROTection:LOWer:DELay {<numeric>|MIN|MAX|DEF}
[SENSe:]VOLTage[:DC]:PROTection:LOWer:DELay? [{MIN|MAX]}
Parameter
Value: | 0.0 to 10.0 (default: 4.0) |
Unit: | S |
Table 4 shows the setting that is specified when *RST or *RCL is sent.
Response
Returns the activation delay time of the voltage sensing undervoltage protection in the NR3 form in response to VOLT:PROT:LOW:DEL?.