Regurated DC Power Supply PWX series

Communication Interface Manual


 

TRIG:TRAN:SOUR

Sets the condition (trigger source) for actually changing the setting after the PWX receives INIT:TRAN.

Command

TRIGger:TRANsient:SOURce {IMMediate|BUS}

TRIGger:TRANsient:SOURce?

Parameter

Value IMM The setting is changed immediately.
  BUS The setting is changed when a software trigger is received (use the *TRG or TRIG:TRAN command to change the setting; default).

For the setting that is applied when *RST is sent, see this table.

Response

Returns the trigger source of the sequence 1 group in CHAR format in response to TRIG:TRAN:SOUR?.

Overview

Setup

Overview of Messages

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Multi channel (VMCB)

Command for DCS

Regurated DC Power SUpplyRegurated DC Power Supply PWX Series