Regurated DC Power Supply PWX series

Communication Interface Manual


 

MEAS:VOLT

Queries the measured value of the voltage output.

Command

MEASure[<n>][:SCALar]:VOLTage[:DC]?

When you are using the multichannel function, use <n> to specify the channel number.

Response

Returns the measured value of the voltage output in NR3 format in response to MEAS:VOLT?.

When you are using the multichannel function, this query returns the measured output voltage of the specified channel in NR3 format in response to MEAS<n>:VOLT?. If you omit <n>, the measured value of the channel that was specified by the INST command is returned.

Unit V

The measured voltage and the measured current are updated alternately at 25 ms intervals. If the measurement is not complete, this query returns the previous measured value in response to MEAS:VOLT?.

Overview

Setup

Overview of Messages

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Multi channel (VMCB)

Command for DCS

Regurated DC Power SUpplyRegurated DC Power Supply PWX Series
Communication Interface Manual