Regurated DC Power Supply PWX series

Communication Interface Manual


 

CURR:TRIG

Sets the current value that is applied when INIT:TRAN and a software trigger are sent.

Command

[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]? {MINimum|MAXimum}

Parameter

Value 0 % to 105 % of the rated output current
(The default value is 105 % of the rated output current.)
Unit A
A SCPI error (-222, "Data out of range") occurs if outside the range.

For the setting that is applied when *RST or *RCL is sent, see this table.

Response

Returns the current value that is applied when a trigger is received in NR3 format in response to CURR:TRIG?.

Overview

Setup

Overview of Messages

Command (function search)

Command (ABC search)