Regurated DC Power Supply PWX series

Communication Interface Manual


 

CURR

Sets the current.

When the PWX is set so that constant current is controlled externally (CURR:EXT:SOUR VOLT), settings performed by this command are invalid.

Command

[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] {<numeric>|MINimum|MAXimum}

[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? {MINimum|MAXimum}

Parameter

Value 0 % to 105 % of the rated output current
(The default value is 105 % of the rated output current.)
Unit A
A SCPI error (-222, "Data out of range") occurs if outside the range.

For the setting that is applied when *RST or *RCL is sent, see this table.

Response

Returns the current setting in NR3 format in response to CURR?.

Overview

Setup

Overview of Messages

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Multi channel (VMCB)

Command for DCS

Regurated DC Power SUpplyRegurated DC Power Supply PWX Series
Communication Interface Manual