TRIG:SOUR
Sets the condition (trigger source) for actually changing the setting after a sequence group 1 receives INIT/ INIT:NAME.
Command
TRIGger[:SEQuence[1]]:SOURce {IMMediate|BUS}
TRIGger[:SEQuence[1]]:SOURce?
TRIGger[:TRANsient]:SOURce {IMMediate|BUS}
TRIGger[:TRANsient]:SOURce?
Parameter
Value | IMM | The setting is changed immediately. |
BUS | The setting is changed when a software trigger is received (use the *TRG, TRIG, or IEEE488.1 get (Group Execute Trigger) command to change the setting; default). |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the trigger source of the sequence 1 group in CHAR format in response to TRIG:SOUR?.