TRIG:SEQ5:SOUR/ TRIG:PROG:SOUR
Sets the condition (trigger source) that determines when the sequence 5 group actually executes a sequence operation after the PCR receives the INIT:SEQ5 PROG or INIT:NAME PROG command.
Command
TRIGger:SEQuence5:SOURce {IMMediate|BUS}
TRIGger:SEQuence5:SOURce?
TRIGger:PROGram:SOURce {IMMediate|BUS}
TRIGger:PROGram:SOURce?
Parameter
Value | IMM | The sequence starts immediately (default). |
BUS | The PCR waits for a software trigger (a *TRG, TRIG:SEQ3, or IEEE 488.1 get (Group Execute Trigger) command), and then the sequence starts. |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the sequence 5 group's trigger source in CHAR format in response to TRIG:SEQ5:SOUR? or TRIG:PROG:SOUR?.