AC Power Supply PCR-LE series

AC Power Supply PCR-LE2 series

AC Power Supply PCR-M series

Commnunication Interface Mannual


 

SYST:CONF:WIR

Sets the OUTPUT mode.

This command is not valid when the output is on (OUTP ON).

This command is not valid if the output mode change requires power cycling. In such a case, change it from the front panel.

Command

SYSTem:CONFigure:WIRing {P1|P1W3|P3}

SYSTem:CONFigure:WIRing?

Parameter

Value P1 Single-phase output
  P1W3

Single-phase three-wire output
Valid when the change does not require power cycling.

  P3 Three-phase output
Valid when the change does not require power cycling.

Response

Returns the output phase setting in CHAR format in response to SYST:CONF:WIR?.

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

AC power supply  PCR-M seriesAC Power Supply PCR-LE series