CURR{1|2|3}:OFFS (PCR-LE/ PCR-LE2 only)
Sets the DC current upper limit of each phase.
This command is valid in single-phase three-wire output or three-phase output (optional).
This is valid in DC or AC+DC mode(OUTP:COUP DC|ACDC).
Command
U phase
[SOURce:]CURRent1:OFFSet[:IMMediate] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent1:OFFSet[:IMMediate]? [{MINimum|MAXimum}]
V phase
[SOURce:]CURRent2:OFFSet[:IMMediate] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent2:OFFSet[:IMMediate]? [{MINimum|MAXimum}]
W phase
[SOURce:]CURRent3:OFFSet[:IMMediate] {<numeric>|MINimum|MAXimum}
[SOURce:]CURRent3:OFFSet[:IMMediate]? [{MINimum|MAXimum}]
Parameter
Value | PCR500LE: 0.35 to 3.85 (3.85 by default) PCR1000LE: 0.7 to 7.70 (7.70 by default) PCR2000LE: 1.4 to 15.40 (15.40 by default) PCR3000LE: 2.1 to 23.10 (23.10 by default) PCR4000LE: 2.80 to 30.80 (30.80 by default) PCR6000LE: 4.2 to 46.20 (46.20 by default) PCR9000LE: 6.3 to 69.30 (69.30 by default) |
Unit | A |
Value | PCR6000LE2: 1.40 to 15.40 (15.40 by default) PCR9000LE2: 2.10 to 23.10 (23.10 by default) PCR12000LE2: 2.80 to 30.80 (30.80 by default) PCR18000LE2: 4.20 to 46.20 (46.20 by default) PCR27000LE2: 6.30 to 69.30 (69.30 by default) |
Unit | A |
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
For the setting that is applied when *RST is sent, see this table
Response
Response
Returns the DC current upper limit of U phase in NR3 format in response to CURR1:OFFS?.
Returns the DC current upper limit of V phase in NR3 format in response to CURR2:OFFS?.
Returns the DC current upper limit of W phase in NR3 format in response to CURR3:OFFS?.