QUEStionable status register (PCR-LE/PCR-LE2)
The QUEStionable status register is a 16-bit register that stores information related to the questionable events and status during PCR operation.
These register bits may indicate problems with the measured data of the PCR.
Bit | Bit weight | Bit name | Description |
---|---|---|---|
0 | 1 | OV(Over Voltage Protection) | Overvoltage protection has been activated |
1 | 2 | OC(Over Current Protection) | Overcurrent protection has been activated |
2 | 4 | PU | Device error has occurred |
3 | 8 | UV(Under Voltage Protection) | Undervoltage protection has been activated |
4 | 16 | OHP(Over Heat Protection) | Overtemperature protection has been activated |
5 | 32 | SHUT DOWN | Shut down the output |
6 | 64 | OCP2 | Overcurrent internal semiconductor protection has been activated |
7 | 128 | NOT USED | -- |
8 | 256 | CAL(CALibration) | Calibration data is invalid |
9 | 512 | OP(Over Power protection) | Overpower protection has been activated |
10 | 1024 | CL-PEAK | Current limit control has been activated |
11 | 2048 | Not Used | -- |
12 | 4096 | CL-RMS(Current Limit on RMS) | TRIP ENABLE: During overload judgment TRIP DISABL: During output voltage control |
13 | 8192 | INSTrument Summary | Summary bit of QUEStionable:INSTrument sub register |
14 | 16384 | OCP2-W | The PCR-LE/PCR-LE2 is waiting for internal semiconductor protection judgment |
15 | 32768 | Not Used | Always zero |