PLZ-5W Series Electronic Load

Commnunication Interface Mannual


 

Command (function search)

Sequence operations

-> Tutorial

Program configuration

PROG Selects or deselects a program
PROG:CRE Creates a new program of the specified name
PROG:CURR:PROT Sets the current value for overcurrent protection (OCP) in the selected program
PROG:CURR:PROT:STAT Sets the operation when overcurrent protection (OCP) is activated in the selected program
PROG:CVOP:LEV Sets the voltage at +CV (addition of CV mode) application in the selected program
PROG:DEL Deletes the program of the specified name
PROG:LIST? Queries the list of registered programs
PROG:LOOP Sets the number of times that the selected program will repeat
PROG:POW:PROT Sets the power of overpower protection (OPP) in the selected program
PROG:POW:PROT:STAT Sets the operation to be performed when overpower protection (OPP) is activated in the selected program
PROG:REN Changes the name of the selected program
PROG:SAVE Saves the selected program
PROG:VOLT:PROT:LOW Sets the voltage of underpower protection (UVP) in the selected program
PROG:VOLT:PROT:STAT Enables/disables undervoltage protection (UVP) in the selected program

Step configuration

PROG:STEP<n>:DWEL Sets the step execution time at the specified step of the selected program
PROG:STEP<n>:INP Sets load on/off at the specified step of the selected program
PROG:STEP<n>:LEV Sets the load at the specified step of the selected program
PROG:STEP<n>:OUTP Sets load on/off at the specified step of the selected program
PROG:STEP<n>:SLEW Sets the slew rate at the specified step of the selected program
PROG:STEP<n>:TRAN Sets the setting transition method at the specified step of the selected program
PROG:STEP<n>:TRIG:GEN Sets whether to perform trigger output at the specified step of the selected program
PROG:STEP<n>:TRIG:WAIT Sets trigger wait at the specified step of the selected program
PROG:STEPS:COUN Sets the number of steps to be registered to the selected program

Sequence execution

INIT:TRAN:PROG Switches to the sequence trigger wait state in the program selected by PROG
TRIG:ACQ:SOUR Sets the measurement trigger source
TRIG:TRAN:SOUR Sets the source of the trigger to be sent to TRANsient
ABOR Aborts the trigger function

>top

Setup

Overview of Command

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Electronic Load  PLZ-5W seriesElectronic Load PLZ-5W series
Communication Interface Manual