PLZ-5W Series Electronic Load

Commnunication Interface Mannual


 

PROG:CURR:PROT:STAT

Sets the operation to be performed when overcurrent protection (OCP) is activated in the program selected by PROG.

Command

[SOURce:]PROGram[:SELected]:CURRent:PROTection:STATe {ON|OFF|1|0}

[SOURce:]PROGram[:SELected]:CURRent:PROTection:STATe?

Parameter

Value ON(1) Load off (Trip)
OFF(0) Limit output (Limit)
Factory default OFF(0)  

Response

Returns the operation to be performed when OCP in the selected program is activated in boolean format in response to the PROG:CURR:PROT:STAT? query.

Setup

Overview of Command

Command (function search)

Command (ABC search)

Command (Sub-system search)

Register

Appendix

Tutorial

Electronic Load  PLZ-5W seriesElectronic Load PLZ-5W series
Communication Interface Manual