TRIG:TRAN:EXEC?

Queries the execution state of the sequence trigger function and the switching function.

Command

TRIGger:TRANsient:EXECution[:STATe]?

Response

Returns <IDLE|WTG|RUN|SUSP|PULS>, <Step_NR1>, <Loop_NR1> in response to the TRIG:TRAN:EXEC? query.

Response Description
<IDLE|WTG|RUN|SUSP|PULS>

IDLE: Sequence waiting and the switching function is off
WTG: Waiting for triggers
SUSP: Sequence is paused
RUN: Delay time or step in execution
PULS: During switching operation

<Step_NR1> Number of steps of program
<Loop_NR1> Number of loops of program