Sets the voltage and current values for the specified parts (point index) of the I-V characteristics map.

To reflect this setting in the output, send ARB:APPL.

Command

[SOURce:]ARBitrary[:LEVel][:IMMediate]:MAP <index>,{<voltage>|MINimum|MAXimum},{<current>|MINimum|MAXimum}

[SOURce:]ARBitrary[:LEVel][:IMMediate]:MAP? <index>

Parameter <index>

Specifies the point index of the I-V characteristics map

Value 1 to maximum value of ARB:COUN

Parameter <voltage>

Specifies the voltage (Unit: V)

Parameter <current>

Specifies the current (Unit: A)

Example

ARB:MAP 1, 5.0V, 1.0A

Response

Returns the voltage and current values for the specified point index in the NR3 format in response to ARB:MAP?.