RMT CONT SOFTWARE FOR PCR-LE/PCR-WE SD021-PCR-LE

Operation Guide


Using the Phase-Voltage or Line-Voltage Link Function

If you use the phase-voltage or line-voltage link function for single-phase three-wire output or three-phase output, the voltage setting display is linked to the measured voltage display.

If the voltages were set using line voltages, measured line voltages are automatically displayed. If the voltages was set using phase voltages, measured phase voltages are automatically displayed.

1

Tap Option.

An Option window appears.

2

Tap the ON check box for Voltage Set & Monitor Link.

This will enable the phase-voltage or line-voltage link function. Tapping again will clear the check box and disable the function.

You can set a password to manage the settings of the link function.

-> “Locking the Option display and Panel with a Password” (p.26)

SD021-PCR-LERMT CONT SOFTWARE FOR PCR-LE/PCR-WE SD021-PCR-LE
Operation Guide