RMT CONT SOFTWARE FOR PCR-LE/PCR-WE SD021-PCR-LE

Operation Guide


Selecting the Output Method (PCR-LE2/ PCR-WE2 only)

Under Wiring Method, select the output method (single-phase output, single-phase three-wire output, or three-phase output).

Item

Description

Conditions that are not allowed

1P2W

Single-phase output

Output on

Monitoring

1P3W

Single-phase three-wire output

3P

Three-phase output

Output cannot be turned on for a few seconds after the output method is switched.

Single-phase three-wire output and three-phase output use the same OUTPUT terminal block. Depending on how the method is switched, the message “Turn the power back on to validate the setting value” may appear. If this message appears, switching is not possible from SD021-PCR-LE/WE. Switch the output method from the PCR front panel, and turn the POWER switch off and then back on.

After you turn the POWER switch off, wait at least 15 seconds before you turn the POWER switch back on. After turning the power back on, check that the communication interface type is set to LAN. If AUTO IP is set to ON, it may take several tens of seconds before it is displayed.

SD021-PCR-LERMT CONT SOFTWARE FOR PCR-LE/PCR-WE SD021-PCR-LE
Operation Guide