AC power supply PCR-M series

Specifications


General Specifications

  

PCR500M

PCR1000M

PCR2000M

PCR4000M

Insulation resistance

Between

input and chassis,

output and chassis,

input and output

500 Vdc, 30 MΩ or more

Withstand voltage

Between

input and chassis,

output and chassis,

input and output

1.5 kVac, 1 minute

Isolation voltage

±380 Vdc

Earth continuity

25 Aac, 0.1 Ω or less

Electromagnetic Compatibility (EMC)*1, *2

Complies with the requirements of the following directive and standards.

EMC Directive 2014/30/EC

EN 61326-1 (Class A*3 )

EN 61000-3-2 (Class A*3, Group 1*4 )

EN 61000-3-3 (Class A*3, Group 1*4 )

The maximum length of all cables and wires connected to the PCR-M Series must be less than 3 m.

Complies with the requirements of the following directive and standards.

EMC Directive 2014/30/EC

EN 61326-1 (Class A*3 )

The maximum length of all cables and wires connected to the PCR-M Series must be less than 3 m.

Safety *1

Complies with the requirements of the following directive and standard.

Low Voltage Directive 2014/35/EC*2

EN 61010-1 (Class I*5, Pollution Degree2)

Circuit system

PWM inverter system

Environment

Operating environment

Indoor use, Overvoltage Category II

Operating temperature range

00 °C to 40 °C (32 °F to 104 °F)

Storage temperature range

-10 °C to 60 °C (14 °F to 140 °F)

Operating humidity range

20 %rh to 80 %rh (no condensation)

Storage humidity range

90 %rh or less (no condensation)

Altitude

Up to 2000 m

External dimensions

See "Dimensions"

Weight

Approx. 6 kg (13.23 lb)

Approx. 11 kg (24.25 lb)

Approx. 15 kg (33.07 lb)

Approx. 32 kg (70.55 lb)

Input terminal

Inlet

M4

M6

Output terminal

M4

M6

Accessories

Power cord

See "Accessory"

Ferrite core

--

1 pc.

--

Cable tie

--

1 pc.

--

Read This FIrst

1 copy

Quick Reference

English: 1 copy, Japanese: 1 copy

Safety information

1 copy

CD-ROM

1 disc

*1. Does not apply to specially ordered or modified PCR-Ms.

*2. Only on models that have the CE marking on the panel. PCR-M series will not be in compliance with EMC limits if the OUTPUT outlet on the front panel is used. PCR2000M will not be in compliance with EMC limits unless the ferrite core is attached on the load wires.

*3. This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.

*4. This is a Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.

*5. This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded.

*6. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.

TOP

AC power supply PCR-M seriesAC power supply PCR-M series
Specifications