AC power supply PCR-M series
Specifications
Unless specified otherwise, the specifications are for the following settings and conditions.
The warm-up time is 30 minutes (with current flowing).
TYP: Typical values do not guarantee the performance.
set: Indicates the setting.
reading: Indicates the reading.
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
Nominal input voltage |
100 Vac to 120 Vac/ 200 Vac to 240 Vac |
|||
Input voltage range |
90 Vac to 132 Vac/180 Vac to 250 Vac (auto detected when the power is turned on) |
|||
Phase |
Single phase , Two-wire |
|||
Nominal input Frequency |
50 Hz to 60 Hz |
|||
Input frequency range |
47 Hz to 63 Hz |
|||
Apparent power |
800 VA or less |
1600 VA or less |
3200 VA or less |
6400 VA or less |
Power factor *1 |
0.9 (TYP) |
|||
Current (Input voltage 90 Vac to 132 Vac/180 Vac to 250 Vac) |
9 A/ 4.5 A or less |
18 A/ 9A or less |
36 A/ 18 A or less |
72 A/ 36 A or less |
*1. For an output voltage of 100 V/200 V (135 V/270 V range), maximum current, and a load power factor of 1.
AC mode output ratings (AC rms)
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
|
Voltage (Rated voltage range) *1 |
1 V to 135 V / 2 V to 270 V |
||||
Voltage (Preset voltage range) *1 |
0 V to 137.5 V / 0 V to 275.0 V |
||||
Voltage setting resolution |
0.1 V |
||||
Voltage setting accuracy *2 |
±(1 % of set + 0.6 V/1.2 V) |
||||
Output phase |
Single phase , Two-wire |
||||
Maximum current*3 |
5 A / 2.5 A |
10 A / 5 A |
20 A / 10 A |
40 A / 20 A |
|
Maximum peak current *4 |
15 A / 7.5 A |
30 A / 15 A |
60 A / 30 A |
120 A / 60 A |
|
Load power factor |
0 to 1 (leading phase or lagging phase) |
||||
Power capacity |
500 VA |
1000 VA |
2000 VA |
4000 VA |
|
Frequency setting range |
40.0 Hz to 500.0 Hz |
||||
Frequency setting resolution |
0.1 Hz |
||||
Frequency accuracy |
Within ±2 × 10-4 |
*1. 135V/ 270V range
*2. For an output voltage of 13.5 V to 135 V/27 V to 270 V, an output frequency of 45 Hz to 65 Hz, no load, and 23 °C ± 5 °C.
*3. For an output voltage of 1 V to 100 V/2 V to 200 V.
Limited by the power capacity when the output voltage is 100 V to 135 V /200 V to 270 V.
*4. With respect to the capacitor-input rectifying load. Limited by the maximum current.
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
Voltage (Rated voltage range) *1 |
1.4 V to 190 V / 2.8 V to 380 V |
|||
Voltage (Preset voltage range)*1 |
-194.0 V to 194.0 V / -388.0 V to 388.0 V |
|||
Voltage setting resolution |
0.1 V |
|||
Voltage setting accuracy*2 |
±(1 % of set + 0.6 V/1.2 V) |
|||
Maximum current*3 |
4 A / 2 A |
8 A / 4 A |
16 A / 8 A |
32 A / 16 A |
Maximum instantaneous current*4 |
12 A / 6 A |
24 A / 12 A |
48 A / 24 A |
96 A / 48 A |
Power capacity |
400 W |
800 W |
1600 W |
3200 W |
*1. 135V/ 270V range
*2. for an output voltage of 19 V to 190 V/38 V to 380 V, no load, and 23 °C ± 5 °C.
*3. For an output voltage of 1.4 V to 100 V/2.8 V to 200 V. Limited by the power capacity when the output voltage is 100 V to 190 V/200 V to 380 V.
*4. Limited by the maximum current.
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
Line voltage variation*1 |
Within ±0.15 % |
|||
Output current variation (135 V/270 V range)*2 |
For 40 Hz to 100 Hz: Within ±0.15 V/±0.3 V For other frequencies: Within ±0.5 V/±1 V |
|||
Output frequency variation*3 |
Within ±1 % |
|||
Ripple noise*4 |
0.7 Vrms/ 1.4 Vrms (TYP) |
|||
Ambient temperature variation *5 |
100 ppm/ °C (TYP) |
*1. For changes in the rated range.
*2. For an output voltage of 80 V to 135 V/160 V to 270 V, a load power factor of 1, stepwise change from an output current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel.
*3. For an output voltage of 100 V/200 V and a load power factor of 1. Output voltage variation with 55 Hz as reference.
*4. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel.
*5. For an output voltage of 100 V/200 V, an output current of 0 A, and within the operating temperature range.
Output voltage waveform distortion ratio, Output voltage response time, Efficiency
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
Output voltage waveform distortion ratio *1 |
0.5 % or less |
|||
Output voltage response time *2 |
150 µs (TYP) |
|||
Efficiency *3 |
70 % or more |
*1. At an output voltage of 50 V to 135 V/100 V to 270 V, a load power factor of 1, and in AC mode.
*2. For an output voltage of 100 V/200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum current (or its reverse).
*3. For AC mode, at an output voltage of 100 V/200 V, maximum current, load power factor of 1, and an output frequency of 40 Hz to 500 Hz.
RMS, average (AVG), and power (W) are derived using the following equations.
RMS (true rms computation) = √(∑(square of the instantaneous voltage or instantaneous current)/the number of samples.)
AVG = ∑(instantaneous voltage or instantaneous current)/the number of samples
WAC = ∑(instantaneous voltage ´ instantaneous current)/the number of samples
WDC = VAVGxIAVG
Sample period: 100 ms to 125 ms for AC output (an integer multiple of the output waveform period, 125 ms for DC output
Update interval: Approx. 3 times/s, averaging over 3 s when averaging is turned on
|
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
||
Voltage measurement *1 |
Resolution |
0.1 V |
||||
Accuracy (135 V/270 V range)*2 |
For 45 Hz to 65 Hz and DC: ±(0.5 % of reading + 0.3 V/0.6 V) For all other frequencies: ±(0.7 % of reading + 0.9 V/1.8 V) |
|||||
Current measurement*3 |
Resolution |
RMS, AVG |
0.01 A |
0 A to 99.99 A: 0.01 A 100 A or more: 0.1 A |
||
PEAK |
0.01 A |
0.1 A |
||||
Accuracy (135 V/270 V range) |
RMS, AVG*4 |
For 45 Hz to 65 Hz and DC: ±(0.5 % of reading +0.02 A/0.01 A) For all other frequencies: ±(0.7 % of reading +0.04 A/0.02 A) |
For 45 Hz to 65 Hz and DC: ±(0.5 % of reading +0.04 A/0.02 A) For all other frequencies: ±(0.7 % of reading +0.08 A/0.04 A) |
For 45 Hz to 65 Hz and DC: ±(0.5 % of reading +0.08 A/0.04 A) For all other frequencies: ±(0.7 % of reading +0.16 A/0.08 A) |
For 45 Hz to 65 Hz and DC: ±(0.5 % of reading +0.16 A/0.08 A) For all other frequencies: ±(0.7 % of reading +0.32 A/0.16 A) |
|
PEAK*5 |
±(2 % of reading + 0.1 A/0.05 A) (TYP) |
±(2 % of reading + 0.2 A/0.1 A) (TYP) |
±(2 % of reading + 0.4 A/0.2 A) (TYP) |
±(2 % of reading + 0.8 A/0.4 A) (TYP) |
||
Power measurement |
Resolution |
0.1 W, 1 W (For 1000 W or more) |
||||
Accuracy *6 |
±(2 % of reading +0.5 W) |
±(2 % of reading +1 W) |
±(2 % of reading +2 W) |
±(2 % of reading +4 W) |
*1. The voltage display is set to RMS in AC mode and AVG in DC mode.
*2. AC mode: For an output voltage of 13.5 V to 135 V/27 V to 270 V and 23 °C ± 5 °C.
DC mode: For an output voltage of 19 V to 190 V/38 V to 380 V and 23 °C ± 5 °C.
*3. Peak current value holds the maximum value of the absolute value of the peak current for 0.3 s or approximately 5 s.
*4. For a waveform of crest factor 3 or less, an output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C.
*5. For a waveform of crest factor 3 or less, an output current in the range of 5 % to 100 % of the maximum peak current in AC mode, an output current in the range of 5 % to 100 % of the maximum instantaneous current in DC mode, and 23 °C ± 5 °C.
*6. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current, DC or an output frequency of 45 Hz to 65 Hz, a load power factor of 1, and 23 °C ± 5 °C.
AC power supply PCR-M series
Specifications