AC power supply PCR-M series
Operation
The settings can be stored to memory. There are three memories, A, B, and C.
Memories are effective when testing drastic changes in voltage or frequency.
In case the optional interface board is installed in the optional slot on the rear panel, the setting condition can be stored up to 10 memories. The memory 4 through 10 can be used only under the remote control operation. For details, see the Communication Interface Manual.
1 |
Configure the PCR-M to the settings you wish to store. |
2 |
Press the STORE key to select the destination memory (A, B, or C). The MEMORY LED on the display illuminates. Memories A, B, and C are selected in order each time the STORE key is pressed, and the corresponding LED illuminates. The upper numeric display indicates the preset voltage. In AC mode, the lower numeric display indicates the preset frequency. |
3 |
Press the ENTER (SHIFT+RECALL) key to store the settings to the memory. The settings are stored to the selected memory. The MEMORY LED on the display turns off. To cancel the storage operation, press a key other than the STORE key or ENTER (SHIFT+RECALL) key. |
Stored Settings |
||
Output mode (AC, DC, or EXT) |
||
Voltage range (135 V, 270 V, or AUTO) |
||
Voltage |
AC |
|
DC |
||
Frequency |
||
Measured value display (RMS, PEAK, AVG, or W) |
||
Limit values |
AC |
Voltage upper limit |
Voltage lower limit |
||
Current limit |
||
Frequency upper limit |
||
Frequency lower limit |
||
DC |
Voltage upper limit |
|
Voltage lower limit |
||
Current limit |
||
Current limit operation |
If a memory is recalled with the OUTPUT turned on, a short alarm sounds and the recalling is disabled when the output mode or voltage range switches. If this happens, turn the OUTPUT off, recall the memory, and then turn the OUTPUT back on.
1 |
Press the RECALL key to select the memory you wish to recall. The MEMORY LED on the display blinks. Memories A, B, and C are selected in order each time the RECALL key is pressed, and the corresponding LED illuminates. The settings stored to memory (preset voltage on the upper numeric display and preset frequency on the lower numeric display) are displayed. |
2 |
Press the ENTER (SHIFT+RECALL) key to recall the settings from the memory. The settings of the selected memory are recalled, and new settings are activated. The MEMORY LED on the display turns off. To cancel the recall operation, press a key other than the RECALL key or ENTER (SHIFT+RECALL) key. |
AC power supply PCR-M series
Operation