AC power supply PCR-M series

Operation


Using Memories

The settings can be stored to memory. There are three memories, A, B, and C.

Memories are effective when testing drastic changes in voltage or frequency.

In case the optional interface board is installed in the optional slot on the rear panel, the setting condition can be stored up to 10 memories. The memory 4 through 10 can be used only under the remote control operation. For details, see the Communication Interface Manual.

24232.jpg

"Saving to the memory"

"Recalling the memory"

Saving to the memory

1

Configure the PCR-M to the settings you wish to store.

2

Press the STORE key to select the destination memory (A, B, or C).

The MEMORY LED on the display illuminates. Memories A, B, and C are selected in order each time the STORE key is pressed, and the corresponding LED illuminates.

The upper numeric display indicates the preset voltage. In AC mode, the lower numeric display indicates the preset frequency.

3

Press the ENTER (SHIFT+RECALL) key to store the settings to the memory.

The settings are stored to the selected memory. The MEMORY LED on the display turns off. To cancel the storage operation, press a key other than the STORE key or ENTER (SHIFT+RECALL) key.

Stored Settings

Output mode (AC, DC, or EXT)

Voltage range (135 V, 270 V, or AUTO)

Voltage

AC

DC

Frequency

Measured value display (RMS, PEAK, AVG, or W)

Limit values

AC

Voltage upper limit

Voltage lower limit

Current limit

Frequency upper limit

Frequency lower limit

DC

Voltage upper limit

Voltage lower limit

Current limit

Current limit operation

TOP

Recalling the memory

If a memory is recalled with the OUTPUT turned on, a short alarm sounds and the recalling is disabled when the output mode or voltage range switches. If this happens, turn the OUTPUT off, recall the memory, and then turn the OUTPUT back on.

1

Press the RECALL key to select the memory you wish to recall.

The MEMORY LED on the display blinks. Memories A, B, and C are selected in order each time the RECALL key is pressed, and the corresponding LED illuminates.

The settings stored to memory (preset voltage on the upper numeric display and preset frequency on the lower numeric display) are displayed.

2

Press the ENTER (SHIFT+RECALL) key to recall the settings from the memory.

The settings of the selected memory are recalled, and new settings are activated. The MEMORY LED on the display turns off. To cancel the recall operation, press a key other than the RECALL key or ENTER (SHIFT+RECALL) key.