AC power supply PCR-M series

Operation


Front panel

25724.jpg

No.

Name

Description

1

POWER

POWER switch. Push ( | ) to turn on; push (29307.jpg) to turn off.

2

Feet

PCR500M/ PCR4000M: Four locations on the bottom

PCR1000M/ PCR2000M: Four locations on the bottom, four locations on the side.

3

OUTLET

Front panel output

4

Air inlet

Air inlet for internal cooling. A dust filter is built in.

5

Handle

Handle for transporting

6

CIRCUIT BREAKER

Reset button of the circuit breaker.

7

ALARM/OVER LOAD

Illuminates when and alarm or overload occurs.

8

Output mode

The selected mode illuminates (AC, DC, or EXT).

9

Upper numeric display

Displays voltage or frequency.

10

Lower numeric display

Displays current or power. Displays the frequency when the memory is used.

11

Key lock/remote

Illuminates when the key is locked or when in remote mode.

12

Rms value, peak value, and average value

RMS, PEAK, or AVG illuminates according to the type of value shown on the numeric display.

13

Memories A, B, and C

The selected memory (A, B, or C) illuminates.

MEMORY illuminates when saving settings and blinks when recalling settings.

14

Voltage range

The selected voltage range (135 V, 270 V, or AUTO) illuminates.

15

I

Selects the type of value shown on the lower numeric display (RMS, PEAK, AVG, or W).

RANGE

Sets the voltage range.

16

LIMIT

Sets the limit value. The key illuminates when active.

ALM CLR

Clears alarms.

17

Rotary knob

Changes the settings.

18

STORE

Saves to the memory (memories A, B, or C).

KEY LOCK

Locks the keys

19

RECALL

Recalls from memory.

ENTER

Confirms memory recall or storage.

20

OUTPUT

Turns the output on/off.

21

CONFIG

Sets the configuration.

22

LOCAL

Switches to local mode.

SHIFT

SHIFT key

23

F

Sets the frequency. The key illuminates when active.

24

V

Sets the voltage. The key illuminates when active.

AC/DC/EXT

Selects the output mode.

30421.jpg CAUTION

Pinch the rotary knob with your fingers to turn it. Turning it rapidly may cause it to malfunction.