AC power supply PCR-M series
Appendix
If you turn the POWER switch on while holding down the RECALL key, all items listed in table are set to factory default settings.
Item |
PCR-M |
|
Output |
Off |
|
Output mode |
AC |
|
Voltage range |
135 V |
|
Voltage |
AC |
0.0 V |
DC |
0.0 V |
|
Frequency |
60.0 Hz |
|
Measured value display |
RMS |
|
Locking the Panel Operation |
Released |
Limit values
Item |
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
|
AC |
Voltage upper limit |
275.0 V |
|||
Voltage lower limit |
0.0 V |
||||
Current limit |
5.25 A |
10.50 A |
21.00 A |
42.00 A |
|
Frequency upper limit |
500.0 Hz |
||||
Frequency lower limit |
40.0 Hz |
||||
DC |
Voltage upper limit |
388.0 V |
|||
Voltage lower limit |
0.0 V |
||||
Current limit |
4.20 A |
8.40 A |
16.80 A |
33.60 A |
|
Current limit operation |
TRIP |
Configuration
Item |
PCR-M |
OUTPUT on phase |
OFF |
Phase angle |
0 deg |
Measured value averaging |
OFF |
Peak hold time |
SHOr (SHORT) |
Communication interface type |
232 (RS232C) |
RS232C baud rate |
19.2 (19200 bps) |
RS232C XON/XOFF control |
On |
GPIB address |
5 |
Communication error trace function |
OFF |
Memory A, B, C
Item |
PCR500M |
PCR1000M |
PCR2000M |
PCR4000M |
|
Voltage |
AC |
0.0 V |
|||
DC |
0.0 V |
||||
Frequency |
60.0 Hz |
||||
Voltage range |
135 V |
||||
Output mode |
AC |
||||
Limit values AC |
Voltage upper limit |
275.0 V |
|||
Voltage lower limit |
0.0 V |
||||
Current limit |
5.25 A |
10.50 A |
21.00 A |
42.00 A |
|
Frequency upper limit |
500.0 Hz |
||||
Frequency lower limit |
40.0 Hz |
||||
Limit values DC |
Voltage upper limit |
388.0 V |
|||
Voltage lower limit |
0.0 V |
||||
Current limit |
4.20 A |
8.40 A |
16.80 A |
33.60 A |
|
Current limit operation |
TRIP |
AC power supply PCR-M series
Appendix