Interface Setup
Interface Setup for PCR-M series
RS232C (standard equipped)
RS232C connection
Turn off the POWER switch on the PCR-M and the computer.
Use a D-sub 9-pin female-to-female AT type crossover cable for the RS232C cable. Figure shows the connector pin assignments.
The KPM1000 does not use hardware handshaking (Crossover cable example2).
9-pin AT type connector
RS232C configuration
1. Press CONFIG until the interface is set to "IntF."
2. Turn the rotary knob to set RS232C to "232."
3. Press CONFIG to set the baud rate to "bAUd."
4. Turn the rotary knob to set the baud rate.
You can set the baud rate to 1.2, 2.4, 4.8, 9.6, or 19.2 (the unit is kBPS).
5. Press CONFIG to set the flow control to "F.CTL" (Xon/Xoff).
6. Turn the rotary knob to select "ON" or "OFF."
7. Wait at least 5 seconds, and then turn the POWER switch off and on.
The settings are applied.
Protocol
The following table shows the settings that correspond to the RS232C protocol.
Underlined values are factory default settings.
Item | Setting |
---|---|
Baudrate |
1 200 bps/ 2 400 bps/ 4 800 bps/ 9 600 bps/ 19 200 bps |
Data | Fixed to 8 bit |
Stop: | Fixed to 1 bit |
Parity | Fixed to none |
Flow | XFLOW/ NONE |
RS232C communication
Use flow control for RS232C communication. DC (device control) codes are used as control codes.
Transmission/reception may not work correctly through unilateral transmission.
Code | Function | ASCII code |
---|---|---|
DC1 (Xon) | Request to send | 11H |
DC3 (Xoff) | Transmission stop request | 13H |
Break signal
The break signal functions as a substitute for the IEEE488.1 dcl / sdc (Device Clear, Selected Device Clear) message.
NOTE