AC power supply PCR-LE series
Appendix
If you attempt to set a value that is not possible, the PCR-LE will generate a beep and an error message.
Error messages and remedies
Error Message |
Error Message |
+102, "Operation denied (OUTPUT ON)" |
Operation is denied because the OUTPUT is on. |
+103 "Operation denied (PROTECTION)" |
Operation is denied because a protection function is activated. |
+104 "Operation denied (OUTPUT COUPLING)" |
Operation is denied because the output mode is invalid. |
+105 "Operation denied (OUTPUT OFF)" |
Operation is denied because the OUTPUT is off. |
+106 "Operation denied (TRIP DISABLE)" |
Operation is denied because the action to perform when the current limit is exceeded is set to "not to turn the output off (DISABLE)." |
+107 "Operation denied (RISE TIME/SIM/SEQ)" |
Operation is denied because soft start, power line abnormality simulation, or sequence is in progress. |
+108 "Operation denied (WIRING METHOD)" |
Operation is denied because the wiring method (single-phase, three-wire; or three-phase) is invalid. |
+109 "Operation denied (EXT.OUTPUT OFF)" |
Operation is denied because the output has been turned off through external control. |
+110 "Operation denied (EXT.SEQ.STOP)" |
Operation is denied because a sequence is being executed or stopped through external control. |
+111 "Operation denied (V-PROG)" |
Operation is denied because the AC voltage output is being controlled with an external signal. |
+112 "Operation denied (SOURCE)" |
Operation is denied because the action is in conflict with the signal source setting. |
+198 "Operation denied (ENTRY)" |
Operation denied because the PCR-LE is waiting for an ENT key input. |
+199 "Operation denied (BUSY)" |
The operation is denied because the PCR-LE is busy. |
+201 "Operation denied (FREQ)" |
The sequence cannot be executed because there is a step whose frequency is outside its limits. |
+202 "Operation denied (VOLT)" |
The sequence cannot be executed because there is a step whose voltage is outside the voltage range or limits. |
+203 “Operation denied (PHASE CHANGE)” |
The sequence cannot be executed because there is a step whose trigger wait setting and sudden phase change setting are both turned on. |
+301 "Setting Conflict (CONPENSATION)" |
Cannot be set because the action is in conflict with the compensation setting. |
+302 "Setting Conflict (CV RESPONSE)" |
Cannot be set because the action is in conflict with the response setting. |
+303 "Setting Conflict (RISE TIME)" |
Cannot be set because the soft start output is in progress or the action is in conflict with the soft start setting. |
+304 "Setting Conflict (SYNCRO)" |
Cannot be set because the synchronization function is in use. |
+305 "Setting Conflict (TRIP)" |
Cannot be set because the action is in conflict with the action that is performed when any of the current limits is exceeded. |
+306 "Setting Conflict (UNBALANCE PHASE)" |
Cannot be set because the phase difference is unbalanced. |
+308 "Setting Conflict (OUTPUT IMPEDANCE)" |
Cannot be set because an output impedance is set. |
+309 "Setting Conflict (WAVE BANK)" |
Cannot be set because a waveform other than waveform bank No. 0 is in use. |
AC power supply PCR-LE series