AC power supply PCR-LE2 series

Appendix


Error Message

If you attempt to set a value that is not possible, the PCR-LE2 will generate a beep and an error message.

79824.jpg 

Error messages and remedies

Error Message

Error Message

+102, "Operation denied (OUTPUT ON)"

Operation is denied because the OUTPUT is on.

+103 "Operation denied (PROTECTION)"

Operation is denied because a protection function is activated.

+104 "Operation denied (OUTPUT COUPLING)"

Operation is denied because the output mode is invalid.

+105 "Operation denied (OUTPUT OFF)"

Operation is denied because the OUTPUT is off.

+106 "Operation denied (TRIP DISABLE)"

Operation is denied because the action to perform when the current limit is exceeded is set to "not to turn the output off (DISABLE)."

+107 "Operation denied (RISE TIME/SIM/SEQ)"

Operation is denied because soft start, power line abnormality simulation, or sequence is in progress.

+108 "Operation denied (WIRING METHOD)"

Operation is denied because the wiring method (single-phase, three-wire; or three-phase) is invalid.

+109 "Operation denied (EXT.OUTPUT OFF)"

Operation is denied because the output has been turned off through external control.

+110 "Operation denied (EXT.SEQ.STOP)"

Operation is denied because a sequence is being executed or stopped through external control.

+111 "Operation denied (V-PROG)"

Operation is denied because the AC voltage output is being controlled with an external signal.

+112 "Operation denied (SOURCE)"

Operation is denied because the action is in conflict with the signal source setting.

+198 "Operation denied (ENTRY)"

Operation denied because the PCR-LE2 is waiting for an ENT key input.

+199 "Operation denied (BUSY)"

The operation is denied because the PCR-LE2 is busy.

+201 "Operation denied (FREQ)"

The sequence cannot be executed because there is a step whose frequency is outside its limits.

+202 "Operation denied (VOLT)"

The sequence cannot be executed because there is a step whose voltage is outside the voltage range or limits.

+203 “Operation denied (PHASE CHANGE)”

The sequence cannot be executed because there is a step whose trigger wait setting and sudden phase change setting are both turned on.

+301 "Setting Conflict (CONPENSATION)"

Cannot be set because the action is in conflict with the compensation setting.

+302 "Setting Conflict (CV RESPONSE)"

Cannot be set because the action is in conflict with the response setting.

+303 "Setting Conflict (RISE TIME)"

Cannot be set because the soft start output is in progress or the action is in conflict with the soft start setting.

+304 "Setting Conflict (SYNCRO)"

Cannot be set because the synchronization function is in use.

+305 "Setting Conflict (TRIP)"

Cannot be set because the action is in conflict with the action that is performed when any of the current limits is exceeded.

+306 "Setting Conflict (UNBALANCE PHASE)"

Cannot be set because the phase difference is unbalanced.

+308 "Setting Conflict (OUTPUT IMPEDANCE)"

Cannot be set because an output impedance is set.

+309 "Setting Conflict (WAVE BANK)"

Cannot be set because a waveform other than waveform bank No. 0 is in use.

 